MAKISHINKO ALL PRODUCTS GUIDE
315/390

JACKE-108Electronic counter654321RESETMODEDISP●Output mode:Available following 5 types output mode.●Key protect:can set up 4 different level.Outline dimension●Pre scale Can set up the relation between input pulse and indication freely. Set range is 0.001-99.999, 4 bits set range is 0.001-9.999. Pre scale value= indication value/pulse, set after calculated. Example:Pre scale value is 0.1 if 10 pulse and 1 indication. Pre scale is 2 if 1 pulse and 2 indication. ●Setting of dicimal position No decimal figure or indicate 3 place(0.0.00.0.000) or 1 digit out of 4. ●Writing Can write desired figure in display. Count start from written value. When reset, counter display value change to written value. ●Reset time Set up the min pulse time of remote set signal. Specify either 2ms or 20ms.If the output mode exceeds standard output, the output time is fixed at HOLD and can operate self-hold which sarisfies the condition.Standard output Equal output Lower limit output Upper limit output Upper/lower limit output Upper/upper limit outputSelection of one short model and hold mode for output time setting mode. (hold 1 and 2 mode for 1st stage and forecast for double setting.) Only output only when count value. Each type and each output will be equal output. Lower limit comparator output, Suitable for positioning. 1st stage setting will be lower limit output. Upper limit comparator output, Suitable for positioning. 1st stage setting will be lower limit output. Upper/lower limit comparator output, Suitable for positioning. 1st stage setting is lower limit output and second stage is upper limit output for double setting. Upper limit 1 and 2 is comparator output. For double setting, first stage will be Upper limit output.●Output time:the output time is once short and hold, hold 1 and hold 2●Acting mode:there are the following 7 types of acting modeHold Hold 1 Hold 2 Once shortA acting B acting C acting D acting E acting F acting G actingSelf hold at setting value Self hold until OUT 2 retum timing Self hold regardless OUT 2. Possible 10ms unit setting.Count during on output Lock count during on output Lock count after output Edge reset on increasing output Edge reset on decreasing output(Can set up time is only one shot) Correspondent to main output for 1 stage setting output 2 stage of double setting, first stage/forecast setting. Corrspondent to suite all types and all output.~ msCorrespondent to forecast output for first stage of double setting, first stage/forecast setting.Level 1 Level 2 Level 3 Level 4Program prohibition Program prohibition, front reset prohibition Program prohibition, pre set prohibition Program prohibition, front reset prohibition, pre set prohibitionthe seiected condition from 4 level in program has effect only when the key protect teminal is ON.(Can set up time is only one shot) (Can set up time is only one shot) Over run (no auto reset) Auto reset4848WiringFront size(common for AC,DC)Standard dimension(AC power type)Panel cut dimension45 ×45+0.6 0+0.6 044.599.8The line clips6.2 162117384512910OUT1OUT2POWEREKEY PROTECTIN AIN B12VGNDRESETEdge reset on increasing output indicate latch dunng on outputEdge reset on decreasing output Count lock dunng on output

元のページ 

10秒後に元のページに移動します

※このページを正しく表示するにはFlashPlayer9以上が必要です